Datasheet

Table Of Contents
39.8.21 Standard ID Filter Configuration
Name:  SIDFC
Offset:  0x84
Reset:  0x00000000
Property:  Write-restricted
This register is write-restricted and only writable if bit fields CCCR.CCE = 1 and CCCR.INIT = 1.
Bit 31 30 29 28 27 26 25 24
Access
Reset
Bit 23 22 21 20 19 18 17 16
LSS[7:0]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 15 14 13 12 11 10 9 8
FLSSA[15:8]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 7 6 5 4 3 2 1 0
FLSSA[7:0]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bits 23:16 – LSS[7:0] List Size Standard
Value Description
0
No standard Message ID filter.
1 - 128
Number of standard Message ID filter elements.
> 128
Values greater than 128 are interpreted as 128.
Bits 15:0 – FLSSA[15:0] Filter List Standard Start Address
Start address of standard Message ID filter list. When the CAN module addresses the Message RAM it
addresses 32-bit words, not single bytes. The configurable start addresses are 32-bit word addresses, i.e.
only bits 15 to 2 are evaluated, the two least significant bits are ignored. Bits 1 to 0 will always be read
back as “00”.
SAM D5x/E5x Family Data Sheet
CAN - Control Area Network
© 2019 Microchip Technology Inc.
Datasheet