Datasheet

Table Of Contents
36.8.11 Data
Name:  DATA
Offset:  0x28
Reset:  0x00000000
Property:  Read/Write
Bit 31 30 29 28 27 26 25 24
DATA[31:24]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 23 22 21 20 19 18 17 16
DATA[23:16]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 15 14 13 12 11 10 9 8
DATA[15:8]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 7 6 5 4 3 2 1 0
DATA[7:0]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bits 31:0 – DATA[31:0] Data
The slave data register I/O location (DATA.DATA) provides access to the master transmit and receive
data buffers. Reading valid data or writing data to be transmitted can be successfully done only when
SCL is held low by the slave (STATUS.CLKHOLD is set). An exception occurs when reading the last data
byte after the stop condition has been received.
Accessing DATA.DATA auto-triggers I
2
C bus operations. The operation performed depends on the state
of CTRLB.ACKACT, CTRLB.SMEN and the type of access (read/write).
When CTRLC.DATA32B=1, read and write transactions from/to the DATA register are 32 bit in size.
Otherwise, reads and writes are 8 bit.
SAM D5x/E5x Family Data Sheet
SERCOM I2C – Inter-Integrated Circuit
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 1046