Datasheet

Spartan-7 FPGAs Data Sheet: DC and AC Switching Characteristics
DS189 (v1.9) March 13, 2019 www.xilinx.com
Product Specification 7
Power-On/Off Power Supply Sequencing
The recommended power-on sequence is V
CCINT
, V
CCBRAM
, V
CCAUX
, and V
CCO
to achieve minimum current
draw and ensure that the I/Os are 3-stated at power-on. The recommended power-off sequence is the
reverse of the power-on sequence. If V
CCINT
and V
CCBRAM
have the same recommended voltage levels then
both can be powered by the same supply and ramped simultaneously. If V
CCAUX
and V
CCO
have the same
recommended voltage levels then both can be powered by the same supply and ramped simultaneously.
For V
CCO
voltages of 3.3V in HR I/O banks and configuration bank 0 the following conditions apply.
The voltage difference between V
CCO
and V
CCAUX
must not exceed 2.625V for longer than
T
VCCO2VCCAUX
for each power-on/off cycle to maintain device reliability levels.
The T
VCCO2VCCAUX
time can be allocated in any percentage between the power-on and power-off
ramps.
There is no recommended sequence for supplies not discussed in this section.
I
CCBRAMQ
Quiescent V
CCBRAM
supply current.
XC7S6 111111mA
XC7S15111111mA
XC7S25111111mA
XC7S50222221mA
XC7S75999998mA
XC7S100999998mA
XA7S6 N/A 1 N/A 1 1 N/A mA
XA7S15 N/A 1 N/A 1 1 N/A mA
XA7S25 N/A 1 N/A 1 1 N/A mA
XA7S50 N/A 2 N/A 2 2 N/A mA
XA7S75 N/A 9 N/A 9 9 N/A mA
XA7S100 N/A 9 N/A 9 9 N/A mA
Notes:
1. Typical values are specified at nominal voltage, 85°C junction temperature (T
j
) with single-ended SelectIO™ resources.
2. Typical values are for blank configured devices with no output current loads, no active input pull-up resistors, all I/O pins are 3-state and
floating.
3. Use the Xilinx Power Estimator spreadsheet tool [Ref 6] to estimate static power consumption for conditions other than those specified.
Table 5: Typical Quiescent Supply Current
(1)(2)(3)
(Cont’d)
Symbol Description Device
Speed Grade
Units1.0V 0.95V
-2C -2I -1C -1I -1Q -1LI
Send Feedback