Datasheet
Table Of Contents
- Spartan-7 FPGAs Data Sheet: DC and AC Switching Characteristics
- Introduction
- DC Characteristics
- Power-On/Off Power Supply Sequencing
- DC Input and Output Levels
- AC Switching Characteristics
- Performance Characteristics
- IOB Pad Input/Output/3-State
- I/O Standard Adjustment Measurement Methodology
- Input/Output Logic Switching Characteristics
- Input Serializer/Deserializer Switching Characteristics
- Output Serializer/Deserializer Switching Characteristics
- Input/Output Delay Switching Characteristics
- CLB Switching Characteristics
- CLB Distributed RAM Switching Characteristics (SLICEM Only)
- CLB Shift Register Switching Characteristics (SLICEM Only)
- Block RAM and FIFO Switching Characteristics
- DSP48E1 Switching Characteristics
- Clock Buffers and Networks
- MMCM Switching Characteristics
- PLL Switching Characteristics
- Device Pin-to-Pin Output Parameter Guidelines
- Device Pin-to-Pin Input Parameter Guidelines
- Additional Package Parameter Guidelines
- XADC Specifications
- Configuration Switching Characteristics
- eFUSE Programming Conditions
- References
- Revision History
- Please Read: Important Legal Notices
Spartan-7 FPGAs Data Sheet: DC and AC Switching Characteristics
DS189 (v1.9) March 13, 2019 www.xilinx.com
Product Specification 49
Table 46: Clock-Capable Clock Input Setup and Hold With PLL
Symbol Description Device
V
CCINT
Operating Voltage and Speed
Grade
Units
1.0V 0.95V
-2 -1 -1L
Input Setup and Hold Time Relative to Clock-Capable Clock Input Signal for SSTL15 Standard.
(1)(2)
T
PSPLLCC
/
T
PHPLLCC
No delay clock-capable clock input and
IFF
(3)
with PLL.
XC7S6 3.07/–0.17 3.69/–0.17 3.69/–0.17 ns
XC7S15 3.07/–0.17 3.69/–0.17 3.69/–0.17 ns
XC7S25 3.04/–0.19 3.64/–0.19 3.64/–0.19 ns
XC7S50 3.15/–0.19 3.77/–0.19 3.77/–0.19 ns
XC7S75 3.15/–0.19 3.78/–0.19 3.78/–0.19 ns
XC7S100 3.15/–0.19 3.78/–0.19 3.78/–0.19 ns
XA7S6 3.07/–0.17 3.69/–0.17 N/A ns
XA7S15 3.07/–0.17 3.69/–0.17 N/A ns
XA7S25 3.04/–0.19 3.64/–0.19 N/A ns
XA7S50 3.15/–0.19 3.77/–0.19 N/A ns
XA7S75 3.15/–0.19 3.78/–0.19 N/A ns
XA7S100 3.15/–0.19 3.78/–0.19 N/A ns
Notes:
1. Setup and hold times are measured over worst case conditions (process, voltage, temperature). Setup time is measured relative to the global
clock input signal using the slowest process, highest temperature, and lowest voltage. Hold time is measured relative to the global clock input
signal using the fastest process, lowest temperature, and highest voltage.
2. Use IBIS to determine any duty-cycle distortion incurred using various standards.
3. IFF = Input flip-flop or latch.
Table 47: Data Input Setup and Hold Times Relative to a Forwarded Clock Input Pin Using BUFIO
Symbol Description
V
CCINT
Operating Voltage and Speed
Grade
Units
1.0V 0.95V
-2 -1 -1L
Input Setup and Hold Time Relative to a Forwarded Clock Input Pin Using BUFIO for SSTL15 Standard.
T
PSCS
/T
PHCS
Setup and hold of I/O clock. –0.38/1.46 –0.38/1.73 –0.38/1.76 ns
Send Feedback