Datasheet

Table Of Contents
Table 231.
CLK_SYS_RESUS_STA
TUS Register
Bits Name Description Type Reset
31:1 Reserved. - - -
0 RESUSSED Clock has been resuscitated, correct the error then send
ctrl_clear=1
RO 0x0
FC0_REF_KHZ Register
Description
Reference clock frequency in kHz
Table 232.
FC0_REF_KHZ Register
Bits Name Description Type Reset
31:20 Reserved. - - -
19:0 NONAME RW 0x00000
FC0_MIN_KHZ Register
Description
Minimum pass frequency in kHz. This is optional. Set to 0 if you are not using the pass/fail flags
Table 233.
FC0_MIN_KHZ
Register
Bits Name Description Type Reset
31:25 Reserved. - - -
24:0 NONAME RW 0x0000000
FC0_MAX_KHZ Register
Description
Maximum pass frequency in kHz. This is optional. Set to 0x1ffffff if you are not using the pass/fail flags
Table 234.
FC0_MAX_KHZ
Register
Bits Name Description Type Reset
31:25 Reserved. - - -
24:0 NONAME RW 0x1ffffff
FC0_DELAY Register
Description
Delays the start of frequency counting to allow the mux to settle
Delay is measured in multiples of the reference clock period
Table 235. FC0_DELAY
Register
Bits Name Description Type Reset
31:3 Reserved. - - -
2:0 NONAME RW 0x1
FC0_INTERVAL Register
Description
The test interval is 0.98us * 2interval, but let’s call it 1us * 2interval
The default gives a test interval of 250us
RP2040 Datasheet
2.14. Clocks 184