User Manual

MR24FDB1
19
24G Bio-aware radar interface content
Function
Code
Address
code 1
Address
code 2
Data
Notes
1
Fall radar
data
reporting
0x06
Alarm 0x01
Fall alarm
0x01
Suspected fall 0x00
Real falls 0x01
No falls 0x02
2
Dwell
alarm
0X02
None 0x00
Alarm time
points:
5min/10min/30
min/ 60min
First time 0X01
Second 0x02
Third 0X03
Fourth 0X04
Description.
1) The read/write command is for the upper computer to send commands
to the radar.
2) The report command is for the radar to send information to the upper
computer.
3) Fall sensitivity is 1~10, default is 4, the higher the level, the more
sensitive it is.
4) Human body sensitivity is 1~10 steps, default 7 steps, the higher the
step, the more sensitive it is.