Datasheet

! ! MR24HPB1!
!
!
!
!
!
13
panels, screens and thin partition walls, and can detect moving objects
behind obscurants; however, they cannot penetrate thicker load-bearing
walls, metal doors, etc.
!
Fig. 4 Schematic diagram of horizontal installation
5.1.2. Tilt Mounting
The tilt installation is shown in Figure 5. This installation is mainly for
detecting movement of people in the room and is mainly suitable for hotels,
lobbies and other places.
The radar installation height is recommended to be 2-2.75m; the tilt angle of
the radar is 10° to 30°, with no obvious obstructions or coverings in front of
the radar.
The radar normal direction is aligned with the main detection location to
ensure that the main beam of the radar antenna covers the detection area
and that the radar beam covers the human activity airspace.
In this installation case, the maximum distance for the detection of moving
bodies is L3 ≈ 7 m; the maximum distance for the detection of seated
bodies / micro movements is L2 ≈ 4 m and the maximum distance for the
detection of sleeping bodies is L1 ≈ 3 m.
In this mode, there may be a blind spot for surveillance directly below the
radar and adjacent areas. The static human detection distance is