Manual
User manual/ Technical information
© 2008-2020 Seeed Technology Co., Ltd. All rights reserved. www.seeed.cc
The 38 Page total 50
Group
Name
Measurement Name Unit
G0
Contains all combinations of measurement parameters
AT Air temperature ℃
(default),
℉
AH Air humidity %RH
AP Barometric pressure Pa
(default),
hPa, bar, mmHg, inHg
LX Light intensity Lux
DN Minimum wind direction deg
Dm Maximum wind direction deg
DA Average wind direction deg
SN Minimum wind speed m/s
(default),
km/h, mph, knots
SM Maximum wind speed m/s
(default),
km/h, mph, knots
SA Average wind speed m/s
(default),
km/h, mph, knots
RA Accumulated rainfall mm
(default),
in
RD Duration of rainfall s
RI Rainfall intensity mm/h
(default),
in/h
Rp Maximum rainfall intensity mm/h
(default),
in/h
HT Heating temperature ℃
TILT Fall detection
Modify the Properties of Measurement Parameters
Properties represent some characteristics of the measured data, such as the unit of output
temperature and the interval between data updates.
Temperature and Humidity
Data Update Interval
IB
Query
Send 0XA;IB=? <CR><LF>
Response 0XA;IB=1<CR><LF>
Description The default data updates every 1 second
Setting
Send 0XA;IB=2<CR><LF>
Response 0XA;IB=2<CR><LF>
Description Set the data update interval to 2
seconds, you can choose a value between 1 to 3600
seconds.
Air Temperature Unit UT
Query
Send 0XA; UT=? <CR><LF>
Return 0XA; UT=C<CR><LF>
Description The temperature unit is Celsius
Set up
Send 0XA; UT=F<CR><LF>
Response 0XA; UT=F<CR><LF>
Description
Set the air temperature unit to Fahrenheit.
C=°C, F=°F
Barometric Pressure Unit UP