Manual
User manual/ Technical information
© 2008-2020 Seeed Technology Co., Ltd. All rights reserved. www.seeed.cc
The 37 Page total 50
Description Disable Electronic Compass
Send 0XA;CC=C<CR><LF>
Response 0XA;CC=C<CR><LF>
Description
Enable Geomagnetic compensation,it will start the 30s compensation process, during this time,
the device should be placed horizontally, and rotate evenly along the Z-axis for 1-2 rounds.
Tilt Detect TD
Query
Send 0XA;TD=?<CR><LF>
Response 0XA;TD=Y/N<CR><LF>
Description
Y: Enable tilt detection function
N: Disable tile detection function
Setting
Send 0XA;TD=Y<CR><LF>
Response 0XA;TD=Y<CR><LF>
Description
Set to enable tilt detection function:TILT=0 means the device is placed vertically, TILT=1 means
the device is placed not placed upright.
Send 0XA;TD=N<CR><LF>
Response 0XA;TD=N<CR><LF>
Description Disable tile detection function:the TILT always equals 0 when the device is placed at any position.
Heating HC
Query
Send 0XA; HC =?<CR><LF>
Response 0XA; HC =Y/N<CR><LF>
Description
Y: Enable heating function
N: Disable heating function
Setting
Send 0XA;HC=Y<CR><LF>
Response 0XA;HC=Y<CR><LF>
Description
Set to enable heating function.
When the air temperature is between [5℃, -25℃], the equipment starts to heat up, and the heating
plate heating temperature can go up to 40℃
When the air temperature is greater than 5°C or less than -25°C, the equipment stops heating.
Note: the heating function need extra dedicate 12V-2A power sourcing
Send 0XA;HC=N<CR><LF>
Response 0XA;HC=N<CR><LF>
Description Set to enable heating function.
Command to read sensor data.
For quick reading of all measurements, G0 is the command.
Read all measurements G0
Query
Send 0XA; G0?<CR><LF>
Response
0XA;AT=23.6;AH=56.4;AP=100819.1;LX=93.0;DN=0.0;DM=0.0;DA=0.0;SN=0.0;SM=0.0;SA=0.0;RA
=1.4;RD=60.0;RI=0.0;RP=0.0;HT=-38.4;TILT=0.0<CR><LF>
Description Returns the value of all measurement parameters