ASCII Protocol
4.2.1 Command definition
A Device address, 0 by default
XA Starter, fixed value
; The separator used to distinguish multiple commands
... A command, represented by different strings
? A query term used to query values
= Assignment, which is used to set the value
v The argument, the specific value of the parameter is set
m Sensor measurement
&
Sensor measurements combine character for getting or setting
multiple measurement parameters
<CR><LF> Response terminator
Terms Explanation
Command
Represented by different strings, such as BD for Baud rate and CP for
communication protocol
Data List
A Data List contains multiple sensor measurement types, represented
by an abbreviation of G0.
For example, G0 contains several test types:
AT;AH;AP;LX;DN;DM;DA;SN;SM;SA;RA;RD;RI;RP;HT;TILT