speed
0x0014
Accumulated
rainfall
0~80000 2 R
0x0016
Accumulated
rainfall duration
0~2000000 2 R
0x0018 Rain intensity 0-80000 2 R
0x001A
Maximum
rainfall intensity
0-80000 2 R
Holding
register
0x1000 Device address 1 R/W
The default address is 1
Can be set to 1 - 247
0x1001
Baud rate
1
R/W
The default is 96, which
means 9600.
It can be set to:
12=1200
24=2400
48=4800
96=9600
192=19200
384=38400
576=57600
1152=115200
0x2000 Set the
accumulated
rainfall to 0
1 R/W Write 1 to set accumulated
rainfall to 0. Read back 1 to
confirm that the setting is
finished. Read back 0
indicates that the setting
failed
0x2001
Set the
accumulated
rainfall duration
to 0
1
R/W
Write 1 to set accumulated
rainfall duration to 0. Read
back 1 to confirm that the
setting is finished. Read back
0 indicates that the setting
failed
4.1.3 Modbus-RTU Read
Here is an example of the Modbus Poll tool
(download from https://www.modbustools.com/download.html).