Manual

User manual/ Technical information
© 2008-2020 Seeed Technology Co., Ltd. All rights reserved. www.seeed.cc
The 26 Page total 50
4 Communication Protocols
The device supports the following communication protocols:
Modbus-RTU
The Modbus protocol is a common language applied to
electronic devices. With this protocol, devices can communicate
within their network. It has become a universal industry standard,
widely used in data loggers, sensor equipment, and so on. Based on
this protocol, devices produced by different vendors can
communicate with each other for system integration.
The Modbus protocol is a master-slave protocol. One node is the
host, and the other nodes that use the Modbus protocol to join the
communication are the slave. Each slave has a unique address.
ASCII
The ASCII protocol is a query-response or a question-and-answer
communication protocol in which a host PC uses ASCII characters to
send commands to a device and then receives responses from that
device.
SDI-12
Single-bus-based data communication protocol, is an
asynchronous serial communications protocol for intelligent sensors
that monitor environment data.