Description
The default rainfall duration overflow value is 2,000,000, the unit is second.
This overflow value will only take effect when the CR rainfall counter reset mode is L overflow
reset.
Setting
Send 0XA; DL=3600<CR><LF>
Response 0XA; DL=3600<CR><LF>
Description
Set the rainfall duration overflow value to 3600 seconds.
It ranges between 100 – 2000000 seconds.
Clear the accumulated rainfall CRA
Setting
Send 0XA; CRA=1<CR><LF>
Response 0XA; CRA=1<CR><LF>
Description Clear the accumulated rainfall.
Clear accumulated rainfall
Duration
CRD
Setting
Send 0XA; CRD=1<CR><LF>
Response 0XA; CRD=1<CR><LF>
Description Clear the accumulated rainfall duration.