Datasheet
MIX8410 Electrochemical Oxygen Gas Sensor
Specifications Structure and Dimensions:
Note: All measurements were taken at 20˚C and 50%RH at 1013hP
Operating Note:
* Cutting the contact metal ribbon.
* When soldering the metal ribbons, the soldering tin was forbidden to contact with the sensor.
* Aging the sensor no less than 30 mins before operation.
* Keeping the sensor out of the volatile solvent.
* Prohibit storage and operating the sensor in acidic or alkaline environment.
Item
Specification
Target Gas
Oxygen
Measurement Range
0 ~ 25%
Maximum Overload
30%
Sensitivity
0.1±0.03 mA
Repeatability
±2%
Response Time(T90)
< 10 Seconds
Recommend Resistor
100Ω
Long Term drift
<5% per year
Life Expectancy(in air)
2 Year
Operating Temperature Range
-20 ~ 50˚C
Storage Temperature Range
0 ~ 50˚C
Operating Humidity Range
15 ~ 90% RH, no-condensing
All dimensions in mm
All tolerance ±0.1mm,unless otherwise stated
Shenzhen Mixsen Electronics Co., Ltd
Add.: No.401 wangtang industrial area,
Xilixinwei Village, Nanshan district,
Shenzhen, China
Post:518000
Tel:86-0755-26517272