9 / 23
5:38400bps
PROTOCOL
0x0202 /514
UINT16, read-write
3/6/16
0~1
0: Modbus RTU
1: Modbus ASCII
PARITY
0x0203 /515
UINT16, read-write
3/6/16
0-2
0: No parity bit
1: even parity check
2: Odd Parity bit
DATABITS
0x0204 /516
UINT16, read-write
3/6/16
1
1:8 data bits
STOPBITS
0x0205 /517
UINT16, read-write
3/6/16
0-1
0:1 Stop bit
1:2 Stop bit
RESPONSE
DELAY
0x0206 /518
UINT16, read-write
3/6/16
0-255 corresponds to the 0-2550
milliseconds sensor to receive the host
request for a period of time and then the
delay response. The time delay for
setting the value of *10 milliseconds. Set
to 0 when no delay.
ACTIVE OUTPUT
INTERVAL
0x0207 /519
UINT16, read-write
3/6/16
0-255 corresponds to 0-255 seconds
does not require the host to request, the
sensor to send data at a fixed time
interval. The time interval is set value * 1
second. Set to 0 when the active output
function is prohibited.