AS5600 − Electrical Characteristics
All limits are guaranteed. The parameters with minimum and
maximum values are guaranteed with production tests or SQC
(Statistical Quality Control) methods.
Operating Conditions
Figure 6:
System Electrical Characteristics and Temperature Range
Note(s):
1. For typical magnetic field (60mT) excluding current delivered to the external load and tolerance on polling times.
2. For OTP burn procedure the supply line source resistance should not exceed 1Ohm.
Symbol Parameter Conditions Min Typ Max Units
VDD5V
Positive supply voltage in
5.0V mode
5.0V operation mode
4.5 5.0 5.5 V
During OTP burn procedure
(2)
VDD3V3
Positive supply voltage in
3.3V mode
3.3V operation mode 3.0 3.3 3.6 V
During OTP burn procedure
(2)
3.25 3.3 3.35 V
IDD
Supply current in NOM
(1)
PM = 00
Always on
6.5 mA
lDD_LPM1
Supply current in LPM1
(1)
PM = 01
Polling time = 5ms
3.4 mA
lDD_ LPM2
Supply current in LPM2
(1)
PM = 10
Polling time = 20ms
1.8 mA
lDD_ LPM3
Supply current in LPM3
(1)
PM = 11
Polling time = 100ms
1.5 mA
IDD_BURN
Supply current per bit for
burn procedure
Initial peak, 1 μs 100 mA
Steady burning,<30 μs 40 mA
T
A
Operating temperature -40 125 °C
T
P
Programming
temperature
20 30 °C
Electrical Characteristics