Instructions
RF Explorer Signal Generator User Manual page 7
Specifications
Parameter
Combo
Signal Generator
Baseline
Signal Generator
Notes
Frequency range
100KHz to 6GHz
23.4MHz to 6GHz
Frequency step/resolution
1Khz
1Khz
Frequency stability
100KHz to 250MHz:
±5ppm
250MHz to 6GHz:
±0.5ppm
±0.5ppm
Frequency accuracy
(internal reference)
100KHz to 250MHz:
±10ppm
250MHz to 6GHz:
±1ppm
±1ppm
Output power range
Calibrated: -40 to
+10dBm
Uncalibrated: -60 to
+18dBm
40dBm to -30dBm
in 3dB steps
-10dBm to 0dBm in
3dB steps
See section Power
Levels (Combo model)
Output power resolution
0.25dB
3dB
Output power accuracy
Typical ±1.5dB
Typical ±3dB
See section Power
Levels (Combo model)
Output power stability
Typical ±0.5dB
Typical ±0.5dB
Output amplitude settling time
500uS
500uS
Temporary spurious
may be present while
signal settles
Output protection
25VDC
25VDC
Harmonics
Typical -40dBc
Typical -10dBc
See section Harmonics
filtering
Spurious
Typical less than
-52dBc
Typical less than
-50dBc
See section Spurious
and Phase Noise
Phase Noise
Typical less than
-125dBc/Hz on
1MHz at 1GHz
Typical less than
-125dBc/Hz on
1MHz at 1GHz
See section Spurious
and Phase Noise
Frequency Sweep settling
< 5ms
< 5ms
Amplitude Sweep settling
< 500uS
< 500uS
Sweep hops range
unlimited
unlimited
Functional modes
CW
Frequency Sweep
Amplitude Sweep
Tracking SNA
CW
Frequency Sweep
Amplitude Sweep
Tracking SNA
Tracking requires a
Windows PC computer
and RF Explorer
Spectrum Analyzer
Operating temperature
5-35C
0-45C