Instructions
RF Explorer Signal Generator User Manual page 35
The power and frequency ranges below define the efficiency of the harmonic filtering implemented in the RF
Explorer Signal Generator Combo model.
These values are measured at reference output signal at -20dBm, measuring all harmonics order #2 - #10, as
this is representative of worst-case scenario.
RF Explorer Signal Generator Combo – Harmonics filtering
Frequency range (MHz)
Best case (dBc)
Typical (dBc)
Worst case (dBc)
0.1 – 0.5
-42
-40
-20
0.5-250
-59
-57
-42
250-430
-53
-40
-22
430-630
-53
-45
-35
630-820
-39
-37
-22
820-1960
-50
-43
-34
1960-2500
-30
-26
-20
2500-4600
-50
-40
-27
4600-5200
-42
-33
-24
5200-6000
-46
-42
-37
Usually harmonics have better filtering at higher power levels up to +10dBm, and about the same response