Instructions
RF Explorer Signal Generator User Manual page 15
Using buttons UP and DOWN on this screen will increase or decrease the selected RF power, one
step at a time. It works slightly different depending on the Signal Generator model.
Combo model: For instance, if the unit is at -30.00dBm and the Power Step is defined at 2.5dBm in
POWER MENU, click on UP button once will increase to -27.50dBm, a second click will increase to
-25.00dBm, etc. A click on DOWN button will decrease power by the defined step.
Note: The level is increased up to a maximum of +15dBm and then will circle back to
-60dBm. The opposite is also the case when using DOWN button to -60dBm will circle back to
+15dBm.
Baseline model: For instance if the unit is in High Power:OFF and Level:1 (lowest possible power) a
press on the UP button will increase into High Power:OFF and Level:2. Another press will increase to
Level:3, etc.
Note: The Level is sequentially increased up to the max level Level:4 and, if the High Power is
OFF at that point, it will be set to ON to increase the power in the next increment with UP
button. For instance if the unit is in High Power:OFF and Level:4, the press of UP button will
increase to High Power:ON and Level:1. See section Power Menu (baseline model) on page
23 for more details on power level modes.