Datasheet

56
The Typ numbers indicated in Table 59 and Table 60 are one standard deviation below the mean, measured at room
temperature 25°C. The Min and Max numbers were measured over process corners at room temperature.
Parameter
Test Condition
Min
Typ
Max
Unit
Operating Frequency Range
2400
2483.5
MHz
Receiver Sensitivity PER
At -95dBm
1
%
Receiver Sensitivity Search
At PER 1%
95
dBm
Receiver Interference Rejection PER
At -2 Channel, Alternate Channel, 30dB
1
%
Receiver Interference Rejection PER
At -1 Channel, Adjacent Channel, 0dB
1
%
Receiver Interference Rejection PER
At +1 Channel, Adjacent Channel, 0dB
1
%
Receiver Interference Rejection PER
At +2 Channel, Alternate Channel, 30dB
1
%
Error Vector Magnitude - RMS (EVM)
At Target Power
30
%
Error Vector Magnitude - Offset (EVM)
At Target Power
10
%
Receiver Maximum Input Level of Desired Signal
At -20dBm Input
1
%
Parameter
Test Condition
Min
Typ
Max
Unit
Maximum output power
At highest normal mode power setting
6/16
*
dBm
Minimum output power
At lowest power setting
-27
dBm
Error vector magnitude (Offset-EVM)
As defined by IEEE 802.15.4-2003, which sets a 35% maximum
10
%
Carrier frequency error
-40
+40
ppm
PSD mask relative
3.5 MHz away (Normal)
-20
dBm
PSD mask absolute
100 KHz BW
-30
dBm
*The ARTIK 530 Module default setting is 6dBm for CE. You can change the setting to 16dBm for FCC testing.