Datasheet

42
The power management of the ARTIK 530 Module as described in Figure 5 is controlled by a PMIC. This PMIC contains four
high efficiency DC-DC converters and five LDO regulators. See Table 37 and Table 38 for details on voltage and amperage
ranges and how they are used in the ARTIK 530 Module.
Buck
Powers
Header
Max Current
[mA]
Range [V]
Default [V]
DCDC1
ARM of Main SoC
3000
0.60-3.50
1.0
DCDC2
Core of Main SoC
3000
0.60-3.50
1.0
DCDC3
DDR3 IO Memory
2000
0.60-3.50
1.50
DCDC4
DDR3 Core Memory
2000
0.60-3.50
1.50