Datasheet
DocID17530 Rev 2 33/54
LIS3DH Registers description
54
8 Registers description
8.1 STATUS_REG_AUX (07h)
8.2 OUT_ADC1_L (08h), OUT_ADC1_H (09h)
Auxiliary 10-bit ADC channel 1 conversion. For auxiliary ADC setting refer to Section 3.7:
Auxiliary ADC and temperature sensor.
8.3 OUT_ADC2_L (0Ah), OUT_ADC2_H (0Bh)
Auxiliary 10-bit ADC channel 2 conversion. For auxiliary ADC setting refer to Section 3.7:
Auxiliary ADC and temperature sensor.
8.4 OUT_ADC3_L (0Ch), OUT_ADC3_H (0Dh)
Auxiliary 10-bit ADC channel 3 conversion or temperature sensor data output. Refer to
Section 3.7: Auxiliary ADC and temperature sensor.
Table 22. STATUS_REG_AUX register
321OR 3OR 2OR 1OR 321DA 3DA 2DA 1DA
Table 23. STATUS_REG_AUX description
321OR 1, 2 and 3-axis data overrun. Default value: 0
(0: no overrun has occurred; 1: a new set of data has overwritten the previous set)
3OR 3-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the 3-axis has overwritten the previous data)
2OR 2-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the 2-axis has overwritten the previous data)
1OR 1-axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data for the 1-axis has overwritten the previous data)
321DA 1, 2 and 3-axis new data available. Default value: 0
(0: a new set of data is not yet available; 1: a new set of data is available)
3DA 3-axis new data available. Default value: 0
(0: new data for the 3-axis is not yet available;
1: new data for the 3-axis is available)
2DA 2 -axis new data available. Default value: 0
(0: new data for the 2-axis is not yet available;
1: new data for the 2-axis is available)
1DA 1-axis new data available. Default value: 0
(0: new data for the 1-axis is not yet available;
1: new data for the 1-axis is available)