Datasheet

Register mapping LIS3DH
32/54 DocID17530 Rev 2
Registers marked as Reserved or not listed in the table above must not be changed. Writing
to those registers may cause permanent damage to the device.
The content of the registers that are loaded at boot should not be changed. They contain the
factory calibration values. Their content is automatically restored when the device is
powered up.
The boot procedure is complete about 5 milliseconds after device power-up.
INT1_CFG rw 30 011 0000 00000000
INT1_SRC r 31 011 0001 Output
INT1_THS rw 32 011 0010 00000000
INT1_DURATION rw 33 011 0011 00000000
INT2_CFG rw 34 011 0100 00000000
INT2_SRC r 35 011 0101 Output
INT2_THS rw 36 011 0110 00000000
INT2_DURATION rw 37 011 0111 00000000
CLICK_CFG rw 38 011 1000 00000000
CLICK_SRC r 39 011 1001 Output
CLICK_THS rw 3A 011 1010 00000000
TIME_LIMIT rw 3B 011 1011 00000000
TIME_LATENCY rw 3C 011 1100 00000000
TIME_WINDOW rw 3D 011 1101 00000000
ACT_THS rw 3E 011 1110 00000000
ACT_DUR rw 3F 011 1111 00000000
Table 21. Register address map
Name Type
Register address
Default Comment
Hex Binary