LARA-R2 series - Data Sheet
UBX-16005783 - R15 Electrical specifications Page 25 of 48
4.2 Operating conditions
Unless otherwise indicated, all operating condition specifications are at an ambient temperature
of +25 °C.
Operation beyond the operating conditions is not recommended and extended exposure beyond
them may affect device reliability.
4.2.1 Operating temperature range
Parameter
Min.
Typical
Max.
Unit
Remarks
Normal operating temperature
20
+25
+65
°C
Normal operating temperature range
(fully functional and meet 3GPP specifications)
Extended operating temperature
40
+85
°C
Extended operating temperature range
(RF performance may be affected outside normal
operating range, though module is fully functional)
Table 8: Environmental conditions
4.2.2 Supply/power pins
Symbol
Parameter
Min.
Typical
Max.
Unit
VCC
Module supply normal operating input voltage
17
3.30
3.80
4.40
V
Module supply extended operating input voltage
18
3.00
3.80
4.50
V
Module supply extended operating input voltage
19
2.80
3.80
4.50
V
V_BCKP
Real Time Clock supply input voltage
1.00
1.80
1.90
V
I_BCKP
Real Time Clock supply average current consumption,
at V_BCKP = 1.8 V
2.00
5
µA
Table 9: Input characteristics of the Supply/Power pins
Symbol
Parameter
Min.
Typical
Max.
Unit
VSIM
SIM supply output voltage, with external 1.8 V SIM
1.80
V
SIM supply output voltage, with external 3.0 V SIM
2.90
V
V_BCKP
Real Time Clock supply output voltage
1.80
V
I_BCKP
Real Time Clock supply output current capability
3
mA
V_INT
Generic Digital Interfaces supply output voltage
1.80
V
V_INT_RIPPLE
Generic Digital Interfaces supply output voltage ripple
with power saving disabled (AT+UPSV=0)
15
mVpp
Generic Digital Interfaces supply output voltage ripple
with power saving enabled (AT+UPSV=1 / 2 / 3)
35
mVpp
I_INT
Generic Digital Interfaces supply output current
capability
70
mA
Table 10: Output characteristics of the Supply/Power pins
17
RF performance may be affected when the input voltage at VCC is outside the herein stated normal operating range limits,
though the module is still fully functional when the input voltage at VCC is inside the extended operating range limits.
18
Range defined for the VCC pin #51 (supply input for internal baseband Power Management Unit and transceiver) of LARA-R211
modules, and for all the VCC pins of the other LARA-R2 series modules, and. Input voltage at the related VCC pins must be
above the herein stated extended operating range minimum limit to switch on the LARA-R2 series modules. The LARA-R2
series modules may switch off when the input voltage at the related VCC pins drops below the herein stated extended
operating range minimum limit.
19
Range defined for the VCC pins #52 and #53 (supply input for the internal power amplifier) of LARA-R211 modules.