Datasheet

Datasheet [Page 11]
EMW3166
2. Electrical Parameters
Operating Ratings 2.1
EMW3166 enters an unstable condition whenever the input voltage dips below the minimum value of supply
voltage. This condition must be considered during design of the power supply routing, especially if operating from a
battery.
Table 2 Voltage Conditions
Symbol
Note
Conditions
Specification
Min
Typical
Max
Unit
VDD
Power Supply
3.0
3.3
3.6
V
Special condition
2.3
2.5
3.0
V
Voltage exceeding maximum ratings will cause hardware damage to the module, and working at the maximum
ratings for a long time will affect the reliability of the module.
Current conditions:
Table 3 Current Conditions
Symbol
Note
Max
Unit
I
VDD
Total current into VDD power lines
320
mA
I
O
Output current sunk by any I/O and control pin
25
Output current sourced by any I/O and control pin
-25
Absolute maximum ratings (voltage) 2.2
Stresses above the absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these conditions is not implied. Exposure to maximum rating
conditions for extended periods may affect device reliability.
Absolute maximum ratings:
Table 4 Absolute Maximum Rating
Symbol
Note
Min
Max
Unit
V
DD
Power supply
0.3
4.0
V
V
OUT
Output voltage on 5V tolerance pin
0.3
5.5
V
V
IN
Input voltage on other pins
0.3
V
DD
+0.3
V
Current Consumption 2.3
2.3.1 Microcontroller Subsystem
Typical and maximum current consumption in Run mode: