Datasheet

WS2813-Mini
Intelligent control LED
integrated light source
6
/
8
http://www.world-semi.com
Reflow instruction
1. No more than two times of reflow.
2. Do not beat the colloid surface when the material is heated.
Manual Soldering instruction
1. Soldering iron’s temperature must be under 300, and operating time must be less than 3 seconds.
2. It should be done only once for the manual soldering.
Repairing instruction
Normally, it can’t be repaired after reflow. You need to use double-ended solder iron and make sure that whether it will
do damage to the LEDs characteristics when repairing is inevitable.
Storing and Transporting
1Scope of application
Front side up, moisture-proof and waterproof, no extrusion, no collision and no vibration.
2Storage and its period
1 Room temperature sealed storage: 20℃~30, 40%60%RH, product is valid for ONE week.
2 Moisture-proof sealed storage: 20℃~30, 25%60%RH, product is valid for TWO weeks.
3 Use up with 2 hours after removing from packages.(Environmental conditions for temperature <30,
relative humidity<60%)
Dehumidification
We would recommend to do dehumidification if they exceed the valid storage period of products or dampened due to
other reasons.
Dehumidification Method: 70-75/48±2 Hours
Electrostatic Protection
LED is an electrostatic sensitive component, although the LED products are with excellent anti-static ability, they will
cause a certain damage by any electrostatic discharge. By taking some electrostatic measures to avoid the damages when
using the LEDs, such as wearing anti-static gloves and anti-static bracelet, etc..