Datasheet

2
G3MC Solid State Relays
G
3
M
C
Ratings (at an Ambient Temperature of 25°C)
Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.)
Output
* The load current varies depending on the ambient temperature. Refer to Load Current
vs. Ambient Temperature under Engineering Data.
Characteristics
Engineering Data
Load Current vs. Ambient Temperature
Rated voltage Operating voltage Impedance Must operate voltage level Must release voltage level
5 VDC 4 to 6 VDC 300Ω ± 20% 4 VDC max.
1 VDC min.12 VDC 9.6 to 14.4 VDC 800Ω ± 20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 1.6 kΩ ± 20% 19.2 VDC max.
Item
Model
Applicable load
Rated load voltage Load voltage range Load current Inrush current
G3MC-101P (-VD)
G3MC-101PL (-VD)
100 to 120 VAC
50/60 Hz
75 to 132 VAC
50/60 Hz
0.1 to 1 A *
8 A
(60 Hz, 1 cycle)
G3MC-201P (-VD) (-1)
G3MC-201PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
G3MC-202P (-VD) (-1)
G3MC-202PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
0.1 to 2 A *
30 A
(60 Hz, 1 cycle)
Model
Item
G3MC-101P(-VD) G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
Operate time
1/2 of load power source cycle +
1 ms max.
1 ms max.
1/2 of load power source cycle +
1 ms max.
1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 1 mA max. (at 100 VAC) 1.5 mA max. (at 200 VAC)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between input and output (3,000 VAC, 50/60 Hz for 1 min for G3MC-@@@-VD-1)
Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock resistance 1,000 m/s
2
Storage temperature -30°C to 100°C (with no icing or condensation)
Ambient operating
temperature
-30°C to 80°C (with no icing or condensation)
Ambient operating
humidity
45% to 85%RH
Weight Approx. 2.5 g (Approx. 3.8 g for G3MC-202P(L)(-VD)(-1)
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-202PL(-VD)(-1)
Load current (A)
Ambient temperature (°C)
1.2
1.0
0.8
0.6
0.4
0.2
0
100806040200
?
20
?
30
Load current (A)
2.5
2.0
1.5
1.0
0.5
0
Ambient temperature (°C)
10080604020 250
?
20
?
40