9. Expansion experiment
From the above experimental results, the following conclusions can be drawn:
1) When current is fixed, with the passage of time, the temperature will stabilize at a certain value. This
value is related with the current, the current increases, the stable temperature are greater. At 2A,
stable temperature will be more than 50 ℃, So, when the SSR work, you should not touch it.
2) Combined with Figure 1 and our data, I consider that the Grove – SSR can operator 4A load current at
max.
3) If load current larger than 5A, such as 7A, you should install a fun on it , or other cooling measures,
but it’s not recommended.