Datasheet

26
LDC1612
,
LDC1614
SNOSCY9A DECEMBER 2014REVISED MARCH 2018
www.ti.com
Product Folder Links: LDC1612 LDC1614
Submit Documentation Feedback Copyright © 2014–2018, Texas Instruments Incorporated
7.6.25 Address 0x17, CLOCK_DIVIDERS3 (LDC1614 only)
Figure 38. Address 0x17, CLOCK_DIVIDERS3
15 14 13 12 11 10 9 8
FIN_DIVIDER3 RESERVED FREF_DIVIDER3
7 6 5 4 3 2 1 0
FREF_DIVIDER3
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 24. Address 0x17, CLOCK_DIVIDERS3
Bit Field Type Reset Description
15:12 FIN_DIVIDER3 R/W 0000 Channel 3 Input Divider
Sets the divider for Channel 3 input. Must be set to 2 if the
Sensor frequency is 8.75MHz.
b0000: Reserved. Do not use.
FIN_DIVIDER3 b0001:
ƒ
IN3
= ƒ
SENSOR3
÷FIN_DIVIDER3
11:10 RESERVED R/W 00 Reserved. Set to b00.
9:0 FREF_DIVIDER3 R/W 0x000 Channel 3 Reference Divider
Sets the divider for Channel 3 reference. Use this to scale the
maximum conversion frequency.
0x000: reserved
FREF_DIVIDER3 0x001:
ƒ
REF3
= ƒ
CLK
÷FREF_DIVIDER3
7.6.26 Address 0x18, STATUS
Figure 39. Address 0x18, STATUS
15 14 13 12 11 10 9 8
ERR_CHAN ERR_UR ERR_OR ERR_WD ERR_AHE ERR_ALE ERR_ZC
7 6 5 4 3 2 1 0
RESERVED DRDY RESERVED UNREADCON
V0
UNREADCONV
1
UNREADCONV
2
UNREADCONV
3
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 25. Address 0x18, STATUS Field Descriptions
Bit Field Type Reset Description
15:14 ERR_CHAN R 00 Error Channel
Indicates which channel has generated a Flag or Error. Once
flagged, any reported error is latched and maintained until either
the STATUS register or the DATAx_MSB register corresponding
to the Error Channel is read.
b00: Channel 0 is source of flag or error.
b01: Channel 1 is source of flag or error.
b10: Channel 2 is source of flag or error (LDC1614 only).
b11: Channel 3 is source of flag or error (LDC1614 only).
13 ERR_UR R 0 Conversion Under-range Error
b0: No Conversion Under-range error was recorded since the
last read of the STATUS register.
b1: An active channel has generated a Conversion Under-range
error. Refer to STATUS.ERR_CHAN field to determine which
channel is the source of this error.
12 ERR_OR R 0 Conversion Over-range Error
b0: No Conversion Over-range error was recorded since the last
read of the STATUS register.
b1: An active channel has generated a Conversion Over-range
error. Refer to STATUS.ERR_CHAN field to determine which
channel is the source of this error.