7.6.21 Address 0x13, SETTLECOUNT3 (LDC1614 only)
Figure 34. Address 0x13, SETTLECOUNT3
15 14 13 12 11 10 9 8
SETTLECOUNT3
7 6 5 4 3 2 1 0
SETTLECOUNT3
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 20. Address 0x13, SETTLECOUNT3 Field Descriptions
Bit Field Type Reset Description
15:0 SETTLECOUNT3 R/W 0x0000 Channel 3 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on Channel 3.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled
0x0000: Settle Time (t
S3
)= 32 ÷ ƒ
REF3
0x0001: Settle Time (t
S3
)= 32 ÷ ƒ
REF3
0x0002 - 0xFFFF: Settle Time (t
S3
)= (SETTLECOUNT3ˣ16) ÷
ƒ
REF3
7.6.22 Address 0x14, CLOCK_DIVIDERS0
Figure 35. Address 0x14, CLOCK_DIVIDERS0
15 14 13 12 11 10 9 8
FIN_DIVIDER0 RESERVED FREF_DIVIDER0
7 6 5 4 3 2 1 0
FREF_DIVIDER0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 21. Address 0x14, CLOCK_DIVIDERS0 Field Descriptions
Bit Field Type Reset Description
15:12 FIN_DIVIDER0 R/W
0000 Channel 0 Input Divider
Sets the divider for Channel 0 input. Must be set to ≥2 if the
Sensor frequency is ≥ 8.75MHz
b0000: Reserved. Do not use.
FIN_DIVIDER0 ≥ b0001:
ƒ
in0
= ƒ
SENSOR0
/FIN_DIVIDER0
11:10 RESERVED R/W 00 Reserved. Set to b00.
9:0 FREF_DIVIDER0 R/W
0x000 Channel 0 Reference Divider
Sets the divider for Channel 0 reference. Use this to scale the
maximum conversion frequency.
0x000: Reserved. Do not use.
FREF_DIVIDER0 ≥ 0x001:
ƒ
REF0
= ƒ
CLK
/FREF_DIVIDER0