Datasheet
23
LDC1612
,
LDC1614
www.ti.com
SNOSCY9A –DECEMBER 2014–REVISED MARCH 2018
Product Folder Links: LDC1612 LDC1614
Submit Documentation FeedbackCopyright © 2014–2018, Texas Instruments Incorporated
7.6.19 Address 0x11, SETTLECOUNT1
Figure 32. Address 0x11, SETTLECOUNT1
15 14 13 12 11 10 9 8
SETTLECOUNT1
7 6 5 4 3 2 1 0
SETTLECOUNT1
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 18. Address 0x11, SETTLECOUNT1 Field Descriptions
Bit Field Type Reset Description
15:0 SETTLECOUNT1 R/W 0x0000 Channel 1 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on a Channel 1.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled.
0x0000: Settle Time (t
S1
)= 32 ÷ ƒ
REF1
0x0001: Settle Time (t
S1
)= 32 ÷ ƒ
REF1
0x0002 - 0xFFFF: Settle Time (t
S1
)= (SETTLECOUNT1ˣ16) ÷
ƒ
REF1
7.6.20 Address 0x12, SETTLECOUNT2 (LDC1614 only)
Figure 33. Address 0x12, SETTLECOUNT2
15 14 13 12 11 10 9 8
SETTLECOUNT2
7 6 5 4 3 2 1 0
SETTLECOUNT2
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 19. Address 0x12, SETTLECOUNT2 Field Descriptions
Bit Field Type Reset Description
15:0 SETTLECOUNT2 R/W 0x0000 Channel 2 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on Channel 2.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled.
0x0000: Settle Time (t
S2
)= 32 ÷ ƒ
REF2
0x0001: Settle Time (t
S2
)= 32 ÷ ƒ
REF2
0x0002 - 0xFFFF: Settle Time (t
S2
)= (SETTLECOUNT2ˣ16) ÷
ƒ
REF2