Datasheet

22
LDC1612
,
LDC1614
SNOSCY9A DECEMBER 2014REVISED MARCH 2018
www.ti.com
Product Folder Links: LDC1612 LDC1614
Submit Documentation Feedback Copyright © 2014–2018, Texas Instruments Incorporated
7.6.16 Address 0x0E, OFFSET2 (LDC1614 only)
Figure 29. Address 0x0E, OFFSET2
15 14 13 12 11 10 9 8
OFFSET2
7 6 5 4 3 2 1 0
OFFSET2
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 15. Address 0x0E, OFFSET2 Field Descriptions
Bit Field Type Reset Description
15:0 OFFSET2 R/W 0x0000 Channel 2 Conversion Offset
ƒ
OFFSET_2
= (OFFSET2÷2
16
)׃
REF2
7.6.17 Address 0x0F, OFFSET3 (LDC1614 only)
Figure 30. Address 0x0F, OFFSET3
15 14 13 12 11 10 9 8
OFFSET3
7 6 5 4 3 2 1 0
OFFSET3
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 16. Address 0x0F, OFFSET3 Field Descriptions
Bit Field Type Reset Description
15:0 OFFSET3 R/W 0x0000 Channel 3 Conversion Offset
ƒ
OFFSET3
= (OFFSET3÷2
16
)׃
REF3
7.6.18 Address 0x10, SETTLECOUNT0
Figure 31. Address 0x10, SETTLECOUNT0
15 14 13 12 11 10 9 8
SETTLECOUNT0
7 6 5 4 3 2 1 0
SETTLECOUNT0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 17. Address 0x10, SETTLECOUNT0 Field Descriptions
Bit Field Type Reset Description
15:0 SETTLECOUNT0 R/W 0x0000 Channel 0 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on Channel 0.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled.
0x0000: Settle Time (t
S0
)= 32 ÷ ƒ
REF0
0x0001: Settle Time (t
S0
)= 32 ÷ ƒ
REF0
0x0002 - 0xFFFF: Settle Time (t
S0
)= (SETTLECOUNT0ˣ16) ÷
ƒ
REF0