Datasheet
Data Sheet
BMA456
Page 96
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x5F) INTERNAL_ERROR
DESCRIPTION: Internal error flags
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x5F) INTERNAL_ERROR
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
R
R
n/a
Reset Value
0
0
0
0
Content
reserved
int_err_2
int_err_1
reserved
int_err_1: Internal error flag - long processing time, processing halted
int_err_2: Internal error flag - fatal error, processing halted
Register (0x6A) NVM_CONF
DESCRIPTION: NVM controller mode (Prog/Erase or Read only)
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x6A) NVM_CONF
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
RW
n/a
Reset Value
0
0
0
0
Content
reserved
nvm_prog_en
reserved
nvm_prog_en: Enable NVM programming
nvm_prog_en
0x00
disable
disable
0x01
enable
enable