Datasheet
Data Sheet
BMA456
Page 91
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
any_no_motion_out: Any-motion/No-motion detection output
error_int_out: Error interrupt output
Register (0x58) INT_MAP_DATA
DESCRIPTION: Interrupt mapping hardware interrupts
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x58) INT_MAP_DATA
Bit
7
6
5
4
Read/Write
n/a
RW
RW
RW
Reset Value
0
0
0
0
Content
reserved
int2_drdy
int2_fwm
int2_ffull
Bit
3
2
1
0
Read/Write
n/a
RW
RW
RW
Reset Value
0
0
0
0
Content
reserved
int1_drdy
int1_fwm
int1_ffull
int1_ffull: FIFO Full interrupt mapped to INT1
int1_fwm: FIFO Watermark interrupt mapped to INT1
int1_drdy: Data Ready interrupt mapped to INT1
int2_ffull: FIFO Full interrupt mapped to INT2
int2_fwm: FIFO Watermark interrupt mapped to INT2
int2_drdy: Data Ready interrupt mapped to INT2
Register (0x59) INIT_CTRL
DESCRIPTION: Start initialization
RESET: 0x90
DEFINITION (Go to register map):
Name
Register (0x59) INIT_CTRL
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
1
0
0
1
Content
init_ctrl
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
init_ctrl
init_ctrl: Start initialization