Datasheet

Data Sheet
BMA456
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x2A) INTERNAL_STATUS
DESCRIPTION: Error bits and message indicating internal status
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x2A) INTERNAL_STATUS
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
odr_high_error
odr_50hz_error
axes_remap_erro
r
message
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
message
message: Internal Status Message
message
0x00
not_init
ASIC is not initialized
0x01
init_ok
ASIC initialized
0x02
init_err
Initialization error
0x03
drv_err
Invalid driver
0x04
sns_stop
Sensor stopped
axes_remap_error: Axes remapped wrongly because a source axis is not assigned to more than one
target axis.
odr_50hz_error: The minimum bandwidth conditions are not respected for the features which require
50 Hz data.
odr_high_error: The minimum bandwidth conditions are not respected for the Wakeup Detection.