Datasheet

Data Sheet
BMA456
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x26) FIFO_DATA
DESCRIPTION: FIFO data output register
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x26) FIFO_DATA
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
fifo_data
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
fifo_data
fifo_data: FIFO read data.
Register (0x27) ACTIVITY_TYPE
DESCRIPTION: Step counter activity output(Running, Walking, Still)
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x27) ACTIVITY_TYPE
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
R
R
Reset Value
0
0
0
0
Content
reserved
activity_type_out
activity_type_out: Step counter activity output(Running, Walking, Still)
activity_type_out
0x00
still
user not moving
0x01
walking
user walking
0x02
running
user running
0x03
unknown
unknown state