Datasheet
Data Sheet
BMA456
Page 73
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x1D) INT_STATUS_1
DESCRIPTION: Interrupt Status. Will be cleared on read.
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x1D) INT_STATUS_1
Bit
7
6
5
4
Read/Write
R
n/a
R
n/a
Reset Value
0
0
0
0
Content
acc_drdy_int
reserved
aux_drdy_int
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
R
R
Reset Value
0
0
0
0
Content
reserved
fwm_int
ffull_int
ffull_int: FIFO Full Interrupt
fwm_int: FIFO Watermark Interrupt
aux_drdy_int: Auxiliary sensor data ready interrupt
acc_drdy_int: Accelerometer data ready interrupt
Register (0x1E) STEP_COUNTER_0
DESCRIPTION: Step counting value byte-0
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x1E) STEP_COUNTER_0
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
step_counter_out_0
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
step_counter_out_0
step_counter_out_0: Step counting value byte-0 (least significant byte)