Register (0x0D) DATA_3
DESCRIPTION: AUX_Y(MSB)
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0D) DATA_3
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_y_15_8
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_y_15_8
Register (0x0E) DATA_4
DESCRIPTION: AUX_Z(LSB)
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0E) DATA_4
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_z_7_0
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_z_7_0