Datasheet

Data Sheet
BMA456
BST-BMA456-DS000-01 | Version 1.1 | October 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
aux_err: Error in I2C-Master detected. This flag will be reset when read.
Register (0x03) STATUS
DESCRIPTION: Sensor status flags
RESET: 0x10
DEFINITION (Go to register map):
Name
Register (0x03) STATUS
Bit
7
6
5
4
Read/Write
R
n/a
R
R
Reset Value
0
0
0
1
Content
drdy_acc
reserved
drdy_aux
cmd_rdy
Bit
3
2
1
0
Read/Write
n/a
R
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
aux_man_op
reserved
aux_man_op: ‘1’(‘0’) indicate a (no) manual auxiliary interface operation is ongoing.
cmd_rdy: CMD decoder status. `0´ -> Command in progress `-> Command decoder is ready to
accept a new command
drdy_aux: Data ready for auxiliary sensor. It gets reset when one auxiliary DATA register is read out
drdy_acc: Data ready for accelerometer. It gets reset when one accelerometer DATA register is read
out
Register (0x0A) DATA_0
DESCRIPTION: AUX_X(LSB)
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0A) DATA_0
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_x_7_0
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
aux_x_7_0