Datasheet

Page 95 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x43) GEN1INT_CONFIG31
DESCRIPTION: the registers contain configurations for generic interrupt 1 evaluation
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x43) GEN1INT_CONFIG31
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen1_int_dur_7_0
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen1_int_dur_7_0
gen1_int_dur_7_0: duration for which the condition has to persist until interrupt can be triggered
duration is measured in data samples of selected data source
gen1_int_dur= 256*gen1_int_dur_15_8 + gen1_int_dur_7_0
Register (0x44) GEN1INT_CONFIG4
DESCRIPTION: the registers contain configurations for generic interrupt 1 evaluation
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x44) GEN1INT_CONFIG4
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen1_int_th_refx_7_0
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen1_int_th_refx_7_0
gen1_int_th_refx_7_0: lsb of reference x-axis value for evaluation
gen1_int_refx = gen1_int_th_refx_7_0 + 256*gen1_int_th_refx_11_8