Register (0x32) WKUP_INT_CONFIG3
DESCRIPTION: the register contains configurations for wake-up interrupt
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x32) WKUP_INT_CONFIG3
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
nt_wkup_refy
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
nt_wkup_refy
nt_wkup_refy: reference acceleration y-axis for the wake-up interrupt
the value is a signed integer, either provided by the host (wkup_refu=0) or automatically
the wake-up interrupt calculates abs(acc_x/y/z-int_wkup_refx/y/z)>int_wkup_thres to determine
whether activity is sufficiently high on the x/y/z-axis to cause wake-up
Register (0x33) WKUP_INT_CONFIG4
DESCRIPTION: the register contains configurations for wake-up interrupt
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x33) WKUP_INT_CONFIG4
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
int_wkup_refz
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
int_wkup_refz
int_wkup_refz: reference acceleration z-axis for the wake-up interrupt
the value is a signed integer, either provided by the host (wkup_refu=0) or automatically
the wake-up interrupt calculates abs(acc_x/y/z-int_wkup_refx/y/z)>int_wkup_thres to determine
whether activity is sufficiently high on the x/y/z-axis to cause wake-up