Register (0x2C) AUTOWAKEUP_0
DESCRIPTION: the register contains configurations for auto-wake-up condition.
The auto-wake-up condition is evaluated as soon as the sensor changes into low power mode
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x2C) AUTOWAKEUP_0
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
wakeup_timeout_thres_11_4
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
wakeup_timeout_thres_11_4
wakeup_timeout_thres_11_4: msb of wake-up timeout threshold
timeout= wakeup_timeout_thres_3_0 + 16*wakeup_timeout_thres_11_4
Register (0x2D) AUTOWAKEUP_1
DESCRIPTION: the register contains configurations for auto-wake-up condition.
The auto-wake-up condition is evaluated as soon as the sensor changes into low power mode
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x2D) AUTOWAKEUP_1
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
wakeup_timeout_thres_3_0
Bit
3
2
1
0
Read/Write
n/a
RW
RW
n/a
Reset Value
0
0
0
0
Content
reserved
wkup_timeout
wkup_int
reserved
wkup_int: low power wake-up interrupt
wkup_int
0x00
nowakeup
disable wake-up interrupt
0x01
en-wakeup
enable wake-up interrupt
wkup_timeout: wake-up timeout as source for auto-wake-up condition
wkup_timeout
0x00
no-timeout
timer not used for wake-up
0x01
enab-timeout
timer triggers wake-up