Datasheet
Preliminary Data Sheet
BMA400
Page 82 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x2B) AUTOLOWPOW_1
DESCRIPTION: the registers contain configurations for auto-low-power condition
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x2B) AUTOLOWPOW_1
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
auto_lp_timeout_thres_3_0
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
auto_lp_timeout
gen1_int
drdy_lowpow_tri
g
drdy_lowpow_trig: data ready as source for auto-low-power condition
drdy_lowpow_trig
0x00
notrig
no triggering of low-power
0x01
trig-newdata
new data ready triggers going into low-power
gen1_int: generic interrupt 1 as source for auto-low-power condition
gen1_int
0x00
nodtrig
no triggering of low-power
0x01
trig-gen1
generic interrupt 1 triggers going into low-power
auto_lp_timeout: auto-low-power timeout as source for auto-low-power condition
auto_lp_timeout
0x00
auto_lp_timeout_0
Low-power timeout disabled
0x01
auto_lp_timeout_1
Low-power timeout active, device shall switch into low
power mode as soon timeout counter is expired
0x02
auto_lp_timeout_2
Low-power timeout active, as 01b, but timeout counter
resets if gen2_int is asserted
0x03
auto_lp_timeout_3
same as 10b
auto_lp_timeout_thres_3_0: lsb of auto-low-power timeout threshold
timeout = auto_lp_timeout_thres_3_0 +16*auto_lp_timeout_thres_11_4
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA