fifo_y_en: y-channel data storage control
fifo_y_en
0x00
nostore
do not store y axis data
0x01
store
store y axis data
fifo_z_en: z-channel data storage control
fifo_z_en
0x00
nostore
do not store z axis data
0x01
store
store z axis data
Register (0x27) FIFO_CONFIG1
DESCRIPTION: the registers contain the FIFO control and FIFO configuration settings
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x27) FIFO_CONFIG1
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
fifo_watermark_7_0
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
fifo_watermark_7_0
fifo_watermark_7_0: lsb of fifo watermark threshold configuration:
watermark[byte]= fifo_watermark_7_0 + 256*fifo_watermark_10_8
Register (0x28) FIFO_CONFIG2
DESCRIPTION: the registers contain the FIFO control and FIFO configuration settings
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x28) FIFO_CONFIG2
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
RW
RW
RW
Reset Value
0
0
0
0
Content
reserved
fifo_watermark_10_8