Datasheet
Preliminary Data Sheet
BMA400
Page 77 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
fwm_int2: fifo watermark interrupt is mapped to INT2
drdy_int2: data ready interrupt is mapped to INT2
Register (0x23) INT12_MAP
DESCRIPTION: the registers contain the interrupts mapping to physical pins
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x23) INT12_MAP
Bit
7
6
5
4
Read/Write
RW
RW
n/a
RW
Reset Value
0
0
0
0
Content
actch_int2
tap_int2
reserved
step_int2
Bit
3
2
1
0
Read/Write
RW
RW
n/a
RW
Reset Value
0
0
0
0
Content
actch_int1
tap_int1
reserved
step_int1
step_int1: step detector interrupt is mapped to INT1
step_int1
0x00
nomap
interrupt not mapped to INT1
0x01
mapped to INT1
interrupt mapped to INT1
tap_int1: tap sensing interrupt is mapped to INT1
tap_int1
0x00
nomap
interrupt not mapped to INT1
0x01
mapped to INT1
interrupt mapped to INT1
actch_int1: activity changed interrupt is mapped to INT1
actch_int1
0x00
nomap
interrupt not mapped to INT1
0x01
mapped to INT1
interrupt mapped to INT1
step_int2: step detector interrupt is mapped to INT2
step_int2
0x00
nomap
interrupt not mapped to INT2
0x01
mapped to INT2
interrupt mapped to INT2
tap_int2: tap sensing interrupt is mapped to INT2
tap_int2
0x00
nomap
interrupt not mapped to INT2
0x01
mapped to INT2
interrupt mapped to INT2
actch_int2: activity changed interrupt is mapped to INT2
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA