BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Name
Register (0x21) INT1_MAP
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
drdy_int1
fwm_int1
ffull_int1
ieng_overrun_int
1
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int1
gen1_int1
orientch_int1
wkup_int1
wkup_int1: low power wake-up interrupt is mapped to int1
orientch_int1: orientation changed interrupt is mapped to int1
gen1_int1: generic interrupt 1 is mapped to int1
gen2_int1: generic interrupt 2 is mapped to int1
ieng_overrun_int1: interrupt engine overrun mapped to int1
ffull_int1: fifo full interrupt is mapped to int1
fwm_int1: fifo watermark interrupt is mapped to int1
drdy_int1: data ready interrupt is mapped to int1
Register (0x22) INT2_MAP
DESCRIPTION: The register contains the interrupt to physical INT2 pin mapping
0: interrupt is not mapped to INT2
1: interrupt is mapped to pin INT2
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x22) INT2_MAP
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
drdy_int2
fwm_int2
ffull_int2
ieng_overrun_int
2
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int2
gen1_int2
orientch_int2
wkup_int2
wkup_int2: low power wake-up interrupt is mapped to INT2
orientch_int2: orientation changed interrupt is mapped to INT2
gen1_int2: generic interrupt 1 is mapped to INT2
gen2_int2: generic interrupt 2 is mapped to INT2
ieng_overrun_int2: interrupt engine overrun mapped to int2