Datasheet
Preliminary Data Sheet
BMA400
Page 68 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x10) INT_STAT2
DESCRIPTION: the registers contain the interrupt status bits
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x10) INT_STAT2
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
R
Reset Value
0
0
0
0
Content
reserved
ieng_overrun_st
at
Bit
3
2
1
0
Read/Write
n/a
R
R
R
Reset Value
0
0
0
0
Content
reserved
actch_z_int_stat
actch_y_int_stat
actch_x_int_stat
actch_x_int_stat: x-axis activity change detected: ‘0’ = no change; ‘1’ = changed
actch_y_int_stat: y-axis activity change detected: ‘0’ = no change; ‘1’ = changed
actch_z_int_stat: z-axis activity change detected: ‘0’ = no change; ‘1’ = changed
ieng_overrun_stat: issued when interrupt calculation could not be finished
Register (0x11) TEMP_DATA
DESCRIPTION: the register contains the temperature of the sensor.
The output word of the 8-bit temperature sensor is 2's complement.
It is valid if the accelerometer is in normal mode.
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x11) TEMP_DATA
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
temp_data_7_0
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
temp_data_7_0
temp_data_7_0: Conversion to real temperature is done using the formula
temp=((real)((signed)temp_data))*0.5+23.0