Datasheet
Preliminary Data Sheet
BMA400
Page 67 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
‘0’ = not set; ‘1’ = set
ieng_overrun_stat: issued when interrupt calculation could not be finished
ffull_int_stat: FIFO full interrupt status:
‘0’ = not set; ‘1’ = set (FIFO full)
fwm_int_stat: FIFO watermark interrupt status:
‘0’ = not set; ‘1’ = set
drdy_int_stat: data ready interrupt is status:
‘0’ = not set; ‘1’ = set
Register (0x0F) INT_STAT1
DESCRIPTION: the registers contain the interrupt status bits
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0F) INT_STAT1
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
R
Reset Value
0
0
0
0
Content
reserved
ieng_overrun_st
at
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
d_tap_int_stat
s_tap_int_stat
step_int_stat
step_int_stat: step detector interrupt status:
‘0’ = not set; ‘1’ = set (step detected);
‘2’ = set (step detected plus another step);
‘3’ = not used
s_tap_int_stat: single tap interrupt status:
‘0’ = not set; ‘1’ = set (single tap detected)
d_tap_int_stat: double tap interrupt status:
‘0’ = not set; ‘1’ = set (double tap detected)
ieng_overrun_stat: issued when interrupt calculation could not be finished