Register (0x0D) EVENT
DESCRIPTION: the register contains event bits.
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0D) EVENT
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
n/a
R
Reset Value
0
0
0
0
Content
reserved
por_detected
por_detected: power on reset bit, clear on read
por_detected
0x00
no-por
no power up or softreset detected
0x01
por-detected
power up or softreset detected
Register (0x0E) INT_STAT0
DESCRIPTION: the registers contain the interrupt status bits
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x0E) INT_STAT0
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
drdy_int_stat
fwm_int_stat
ffull_int_stat
ieng_overrun_st
at
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset Value
0
0
0
0
Content
gen2_int_stat
gen1_int_stat
orientch_int_stat
wkup_int_stat
wkup_int_stat: low power wake-up interrupt status:
‘0’ = not set; ‘1’ = set (wake-up condition is valid)
orientch_int_stat: orientation changed interrupt status:
‘0’ = not set; ‘1’ = set (orientation is changed)
gen1_int_stat: generic interrupt 1 status:
‘0’ = not set; ‘1’ = set
gen2_int_stat: generic interrupt 2 status:
Confidential and under NDA