Datasheet
Preliminary Data Sheet
BMA400
Page 60 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x02) ERR_REG
DESCRIPTION: reserved
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x02) ERR_REG
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
R
n/a
Reset Value
0
0
0
0
Content
reserved
cmd_err
reserved
cmd_err: command execution failed. This is a clear-on-read bit.
cmd_err== 0x1: Command execution failed.
Register (0x03) STATUS
DESCRIPTION: the register contains the sensor status bits
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x03) STATUS
Bit
7
6
5
4
Read/Write
R
n/a
n/a
R
Reset Value
0
0
0
0
Content
drdy_stat
reserved
cmd_rdy
Bit
3
2
1
0
Read/Write
n/a
R
R
R
Reset Value
0
0
0
0
Content
reserved
power_mode_stat
int_active
int_active: the int_active bit is set if one of the interrupts is triggered
int_active
0x00
not-triggered
one of the interrupts is triggered
0x01
triggered
one of the interrupts is triggered
power_mode_stat: current power mode of the sensor
power_mode_stat
0x00
sleep_mode
device in sleep mode
0x01
low_power_mode
device in low power mode
0x02
normal_mode
device in normal mode
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA